TEXAS INDUSTRIES, INC. -- PORTLAND CEMENT -- 5610-00-242-3792
===================== Product Identification =====================
Product ID:PORTLAND CEMENT
MSDS Date:11/01/1985
FSC:5610
NIIN:00-242-3792
=== Responsible Party ===
Company Name:TEXAS INDUSTRIES, INC.
Address:715 AVE H. EAST
City:ARLINGTON
State:TX
ZIP:76010
Info Phone Num:(817) 640-1701
Emergency Phone Num:(817) 640-1701
CAGE:0B3F8
=== Contractor Identification ===
Company Name:TEXAS INDUSTRIES, INC
Address:715 AVE H. EAST
Box:City:ARLINGTON
State:TX
ZIP:76010
Phone:(214) 637-3100
CAGE:0B3F8
============= Composition/Information on Ingredients =============
Ingred Name:PORTLAND CEMENT
CAS:65997-15-1
RTECS #:VV8770000
Fraction by Wt: 58%
Other REC Limits:50 MPPCF (MSHA)
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9293
Ingred Name:CALCIUM CARBONATE (MARBLE) (LIMESTONE)
CAS:1317-65-3
RTECS #:EV9580000
Fraction by Wt: 40%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9192
Ingred Name:GYPSUM
CAS:13397-24-5
RTECS #:MG2360000
Fraction by Wt: 2%
Other REC Limits:5 MG/CUM RESP DUST
OSHA PEL:15 MG/CUM TOTAL DUST
ACGIH TLV:10 MG/CUM
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES/SKIN: DUST CAN CAUSE
INFLLAMMATION OF THE CORNEA, IRRITATION & ALKALI BURNS. INHALATION:
IRRITATION TO NASAL PASSAGES, PULMONARY DISEASES, PNEUMONOCONIOSIS
& SILICOSIS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES/SKIN: DUST CAN CAUSE INFLAMMATION OF THE
CORNEA, IRRITATION, ALKALI BURNS, & ALLERGIC DERMATITIS.
INHALATION: IRRITATION TO NASAL PASSAGES, PULMONARY DISEASES,
PNEUMONOCONIOSIS & SILICOSIS.
Medical Cond Aggravated by Exposure:RESPIRATORY DISORDERS/DISEASES,
DERMATITIS, OTHER SKIN DISORDERS, & HYPERSENSITIVE.
======================= First Aid Measures =======================
First Aid:EYES: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS. SKIN:
WASH W/SOAP & WATER. INHALATION: REMOVE TO FRESH AIR. GIVE CPR OR
OXYGEN IF NEEDED. OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point:WILL NOT IGNITE
Unusual Fire/Explosion Hazard:CONTACT W/STRONG ACIDS MAY PRODUCE A
VIOLENT, EXOTHERMIC REACTION & MAY EVOLVE TOXIC GASES OR VAPORS,
DEPENDING UPON THE ACID INVOLVED.
================== Accidental Release Measures ==================
Spill Release Procedures:CLEAN-UP OF SPILLS MAY REQUIRE PERSONAL
PROTECTION EQUIPMENT.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE AWAY FROM STRONG ACIDS.
UNINTENTIONAL CONTACT W/WATER SHOULD BE AVOIDED TO PRESERVE
PRODUCT. MATERIAL IS HIGHLY ALKALINE.
Other Precautions:AVOID CONTACT W/SKIN, EYES & CLOTHING.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH/MSHA APPROVED FOR PROTECTION AGAINST
SILICA & NUISANCE DUSTS.
Ventilation:PROVIDE MECHANICAL/LOCAL EXHAUST VENTILATION TO KEEP