SYSTEMS SCIENTIFIC LABORATORIES INC -- POTASSIUM PERSULFATE SOLUTION -- 6810-00N018176
===================== Product Identification =====================
Product ID:POTASSIUM PERSULFATE SOLUTION
MSDS Date:12/03/1990
FSC:6810
NIIN:00N018176
=== Responsible Party ===
Company Name:SYSTEMS SCIENTIFIC LABORATORIES INC
Address:1295 BOULEVARD WAY
City:WALNUT CREEK
State:CA
ZIP:94595
Country:US
Info Phone Num:415-937-6748
Emergency Phone Num:415-937-6748
Preparer's Name:JAMES P GILLEENY
CAGE:3R657
=== Contractor Identification ===
Company Name:SYSTEMS SCIENTIFIC LAB INC
Address:1295 BOULEVARD WAY
Box:City:WALNUT CREEK
State:CA
ZIP:94595
Country:US
Phone:415-937-6748
CAGE:3R657
============= Composition/Information on Ingredients =============
Ingred Name:PEROXYDISULFURIC ACID, DIPOTASSIUM SALT; (POTASSIUM
PERSULFATE)
CAS:7727-21-1
RTECS #:SE0400000
ACGIH TLV:5 MG(S*2O*8)/M3
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:AVOID CONTACT WITH EYES AND SKIN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:SKIN: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. EYES: FLUSH
WITH WATER FOR AT LEAST 15 MINUTES. CONTACT MD. INGEST: CALL MD
IMMEDIATELY . INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
O2/A RTF RESP) .
===================== Fire Fighting Measures =====================
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
================== Accidental Release Measures ==================
Spill Release Procedures:SCOOP UP AND PLACE IN A SUITABLE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED DUST MASK.
Ventilation:LOCAL/MECHANICAL (GENERAL) ACCEPTABLE.
Protective Gloves:RUBBER.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:D1
Melt/Freeze Pt:M.P/F.P Text:<212F,<100C
Decomp Temp:Decomp Text:<212F,<100C
Spec Gravity:2.5
Solubility in Water:1.8%
Appearance and Odor:COLORLESS LIQUID
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
REDUCING AGENTS, OXIDIZABLE MATERIALS
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER
Hazardous Decomposition Products:WHEN HEATED TO DECOMPOSITION, EMITS
TOXIC FUMES OF SOX.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF BY MEANS AS TO COMPLY WITH ALL LOCAL,
STATE AND FEDERAL REGULATIONS OR CONTACT AN APPROVED AND LICENSED
DISPOSAL AGENCY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.